Tripp Lite by Eaton PDU 5.5kW Single-Phase Monitored Per-Outlet PDU - LX Platform 24 Outlets (208/230V) L6-30P Input 0U TAA

Monitored - NEMA L6-30P - 20 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical/Toolless - Rack-mountable - TAA Compliant

0.0 (0)

Vendor : Tripp Lite

VPN # : PDUNVR30HVLX

✔ In Stock (5)

$ 1,904.24
MSRP $ 3,199.23 excl. tax

Return Policy: Returnable

Committed to better shopping experiences

Delivering value with every purchase

Support Everyday

Support from 8:30 AM to 10:00 PM everyday

  • ✔ Returnable
  • ✔ Authorized to Purchase
  • ✔ Warranty Included

Tripp Lite series PDUNVR30HVLX 24-Outlets PDU - Monitored - NEMA L6-30P - 20 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical/Toolless - Rack-mountable

Additional Information
Summary Tripp Lite series PDUNVR30HVLX 24-Outlets PDU - Monitored - NEMA L6-30P - 20 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical/Toolless - Rack-mountable
Stock In Stock (5)
Seller Orders
Brand Tripp Lite
Quality label
SKU 120VVL
VPN # PDUNVR30HVLX
UPC 0037332242280

Tech Specs

Manufacturer
Eaton Corporation
Manufacturer Part Number
PDUNVR30HVLX
Manufacturer Website Address
Brand Name
Tripp Lite series
Product Model
PDUNVR30HVLX
Product Name
PDUNVR30HVLX 24-Outlets PDU
Marketing Information

5.8kW Single-Phase PDU Distributes and Monitors Network-Grade Power

This monitored PDU provides real-time remote monitoring of voltage and load levels via its built-in network interface. Ideal for your small-to-mid-sized data center, computer room or high-density network closet, the PDUNVR30HVLX features 20 C13 and 4 C19 208/240V outlets in two breakered load banks, which distribute AC power to rack equipment. Advanced network power monitoring provides 1% billing-grade power consumption data for devices connected to each outlet.

Monitored Per-Outlet PDU Lets You Keep Track of Power Consumption in Real Time

Not only can you remotely monitor voltage and frequency, but the PDUNVR30HVLX also allows metering of input current, as well as output current per bank and per outlet. Banks can be individually monitored to ensure proper load balance and prevent downtime. Monitoring each outlet allows you to study power consumption trends for each connected device. This helps you detect hardware problems and network traffic bottlenecks, as well as compare power usage among various devices.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, Telnet or SSH. Full 10/100/1000 Mbps auto-sensing enables optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities.

Auto Probe Allows Autonomous PDU Management

The LX Platform interface allows use of Tripp Lite's IP-based Auto Probe feature, which ensures continuous network uptime by communicating with other network devices. If communication is lost, Auto Probe autonomously performs one or more user-configurable actions that help you return the network devices to an operational state, including email notifications. The innovative Auto Probe is especially ideal for ATMs, retail kiosks, digital signage, edge computing and PC gaming centers.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the load for each outlet bank separately and the total connected load. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment.

Easy to Install Vertically in an EIA-Standard 19 in. Rack

The 70-inch 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A 10-foot cord with a NEMA L6-30P input connects the PDU to a compatible AC power source, such as a generator or protected UPS.

TAA-Compliant for GSA Schedule Purchases

The PDUNVR30HVLX is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Product Type
PDU
PDU Type
Monitored
Phase
Single Phase
Plug/Connector Type
NEMA L6-30P
Receptacle Type
IEC 60320 C19
Receptacle Detail
4 x IEC 60320 C19
Protection Type
Overload Protection
Input Voltage
230 V AC
Output Voltage
240 V AC
Power Rating (Watt)
5800 W
Input Current
30 A
Management
  • SNMP
  • Telnet
  • SSH
Network (RJ-45)
Yes
Mounting Orientation
Vertical/Toolless
Mount Type
Rack-mountable
Rack Height
0U
Height
70"
Width
2.2"
Depth
2.6"
Weight (Approximate)
12 lb
Package Contents
  • PDUNVR30HVLX 24-Outlets PDU
  • Built-in LX Platform Interface
  • Configuration Cable
  • 20 x C13 Plug-Lock Inserts
  • 4 x C19 Plug-Lock Inserts
  • Rack-Mounting Hardware
  • PDUMVROTATEBRKT Mounting Bracket Accessory
  • Owner's Manual
Country of Origin
Taiwan
TAA Compliant
Yes
Environmentally Friendly
Yes
Environmental Compliance
Restriction of Hazardous Substances (RoHS)
Limited Warranty
2 Year